DIGITEL High Volume
Sampler![]() for autonomous, continuous measurements. |
| Construction | DHA-80 in field housing |
DHA-80 in mounting rack 19'' |
DHA-80 in box housing |
DH-77 in field housing |
DS-02 in field housing |
| Illustration | |||||
| Technical data | |||||
| Type of construction | field housing | mounting rack 19“ | box housing | field housing | field housing |
| Power Supply | 230V +6/-10% 50Hz max.1700VA |
230V +6/-10% |
230V +6/-10% 50Hz max.1700VA |
230V +6/-10% 50Hz max.1700VA |
230V +6/-10% 50Hz max.1700VA |
| Fuse protection | 10A | 10A | 10A | 10A | 10A |
Specification connection cable |
3 x 1,0 mm² 10 A 250 V |
3 x 1,0 mm² 10 A 250 V |
3 x 1,0 mm² 10 A 250 V |
3 x 1,0 mm² 10 A 250 V |
3 x 1,0 mm² 10 A 250 V |
| Installation | Category II (Standard power) |
Category II (Standard power) |
Category II (Standard power) |
Category II (Standard power) |
Category II (Standard power) |
| Field of application | 5... 40 °C 10 ... 90 % rF resp.. -20 ... 40 °C 10 ... 95 % rF with Interior heating max. operation altitude: 2000 m. above sealevel.* |
5... 40 °C 10 ... 90 % rF resp.. -20 ... 40 °C 10 ... 95 % rF with Interior heating max. operation altitude: 2000 m. above sealevel.* |
5... 40 °C 10 ... 90 % rF resp.. -20 ... 40 °C 10 ... 95 % rF with Interior heating max. operation altitude: 2000 m. above sealevel.* |
5... 40 °C 10 ... 90 % rF resp.. -20 ... 40 °C 10 ... 95 % rF with Interior heating max. operation altitude: 2000 m. above sealevel.* |
5... 40 °C 10 ... 90 % rF resp.. -20 ... 40 °C 10 ... 95 % rF with Interior heating max. operation altitude: 2000 m. above sealevel.* |
| Flow rate | 100 - 1000 l/min | 100 - 1000 l/min | 100 - 1000 l/min | 100 - 1000 l/min | 100 - 1000 l/min |
| „Volume flow“ control accuracy | < 5% of MBE | < 5% of MBE | < 5% of MBE | < 5% of MBE | < 5% of MBE |
| Blower, average durability | 36.000 h | 36.000 h | 36.000 h | 36.000 h | 36.000 h |
| reproducible accuracy settings (according to UMEG-report Nr. 6-08/00) | +- 0,45% | +- 0,45% | +- 0,45% | +- 0,45% | +- 0,45% |
| Accuracy logged standards and measured volumes: | <+/- 2% | <+/- 2% | <+/- 2% | <+/- 2% | <+/- 2% |
| Time programs | Work, Pause ( 0 ... 59999 minutes each) Start time adjustable using date and time. |
Work, Pause ( 0 ... 59999 minutes each) Start time adjustable using date and time. |
Work, Pause ( 0 ... 59999 minutes each) Start time adjustable using date and time. |
Work, Pause ( 0 ... 59999 minutes each) Start time adjustable using date and time. |
Work, Pause ( 0 ... 59999 minutes each) Start time adjustable using date and time. |
| Outer dimensions |
1355 x 600 x 250 mm (H x W x D) |
960 x 483 x 500 mm (H x W x D) |
1260 x 528 x 250 mm (H x W x D) |
1155 x 600 x 250 mm (H x W x D) |
855 x 500 x 250 mm (H x W x D) |
| Weight | 60 kg | 45 kg | 43 kg | 46 kg | 35 kg |
| Protection class | IP54 | IP50 | IP50 | IP54 | IP54 |
| Filter | 15 round filter d = 150 mm (flowing area: d = 140 mm) Filter material depends on the aim of analysis |
15 round filter d = 150 mm (flowing area: d = 140 mm) Filter material depends on the aim of analysis |
15 round filter d = 150 mm (flowing area: d = 140 mm) Filter material depends on the aim of analysis |
1 round filter d = 150 mm (flowing area: d = 140 mm) Filter material depends on the aim of analysis |
extern |
| Underpressure at 1000 l/min | max. 130 mbar | max. 130 mbar | max. 130 mbar | max. 130 mbar | max. 130 mbar |
| Automatic filter exchange | yes |
yes |
yes |
no |
no |
| Identification changer failure | yes |
yes |
yes |
no |
no |
| Manual filter exchange | yes |
yes |
yes |
yes |
no |
| Identification filter magazine empty | yes |
yes |
yes |
no |
no |
| Analogue remote control | yes |
yes |
yes |
yes |
yes |
| Remote control via RS-232C | yes |
yes |
yes |
yes |
yes |
| Logging via RS-232C | yes |
yes |
yes |
yes |
yes |
| Switch-off overloading | yes |
yes |
yes |
yes |
yes |
| Counter operation hours | yes |
yes |
yes |
yes |
yes |
| Indication motor-load | yes |
yes |
yes |
yes |
yes |
| Multi-langual logging | yes |
yes |
yes |
yes |
yes |
| Battery-backed data memory | yes |
yes |
yes |
yes |
yes |
| Battery-backed clock module | yes (+/- 4 sec. /day) |
yes (+/- 4 sec. / day) |
yes (+/- 4 sec. / day) |
yes (+/- 4 sec. / day) |
yes (+/- 4 sec. / day) |
| Power consumption per day at a nozzle capacity of 75% and an activated inlet heating | approx. 30 kWh | approx. 30 kWh | approx. 30 kWh | approx. 30 kWh | approx. 30 kWh |
| Activation inlet heating | 30V / 50Hz |
30V / 50Hz 160 VA max. |
30V / 50Hz 160 VA max. |
Option | Option |
| Options | |||||
| Activation inlet heating | Standard | Standard | Standard | 30V / 50Hz / 160 VA max. | 30V / 50Hz / 160 VA max. |
| inlet | TSP, PM10, PM 2,5, PM1 |
TSP, PM10, PM 2,5, PM1 |
TSP, PM10, PM 2,5, PM1 |
TSP, PM10, PM 2,5, PM1 |
PM10, PM 2,5, PM1 with integrated filter holder |
| Logging of pressure and temperature at inlet | yes |
yes |
yes |
no |
no |
| PAH cartridge holder | d = 100 x 140 mm |
no |
d = 100 x 140 mm |
d = 100 x 140 mm |
external |
| PAH cartridge changer | d = 60 x 100 mm |
no |
no |
no |
no |
| Memory cards (PCMCIA) to RS-232C interface |
yes |
yes |
yes |
yes |
yes |
| Memory cards (PCMCIA) internal | yes |
yes |
yes |
no |
no |
| Log printer | yes |
yes |
yes |
yes |
yes |
| Interface logging | DIGITEL, Bayern-Hessen-protocol, AK-protocol, user specific | DIGITEL, Bayern-Hessen-protocol, AK-protocol, user specific | DIGITEL, Bayern-Hessen-protocol, AK-protocol, user specific | DIGITEL, Bayern-Hessen-protocol, AK-protocol, user specific | DIGITEL, Bayern-Hessen-protocol, AK-protocol, user specific |
| Network connection (Ethernet) | yes |
yes |
yes |
yes |
yes |
| Ext. meteo data logging | yes |
yes |
yes |
no |
no |
* Special construction for operation altitude over 2000 m. above sea level on request Dimension drawings: DHA-80
Field housing (pdf, ca. 667 kByte) Noise level: |